Sign In | Join Free | My carsrow.com |
|
Brand Name : KACISE
Model Number : KGD-SF-501
Certification : CE
Place of Origin : CHINA
MOQ : 1PCS
Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
Supply Ability : 1000 Piece/Pieces per Week negotiable
Delivery Time : 5-8 work days
Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available
Linear Error : ±1%F.S.
Repeatability : ≤1%
Preheating Time : 45min
Zero - point Drift : ±3%F.S./7d
Range - point Drift : ±3%F.S./7d
Supply Voltage : 100 - 240VAC
KGD - SF - 501 Online Monitoring System
Product Introduction
The KGD - SF - 501 Online Monitoring System is a high - performance gas analysis instrument. Based on the principles of Ultraviolet Differential Optical Absorption Spectroscopy (UV - DOAS) and Non - Dispersive Infrared (NDIR) measurement technology, it adopts a reliable and stable light source, high - performance detector, and precise signal processing circuit. It features high measurement accuracy, strong anti - interference ability, and stable performance during long - term use. It is especially suitable for measuring low - concentration SO2, H2S, and CO components in the gas decomposition products of KGD - SF - 501.
The system consists of a light source, a gas cell, and a detector. Using UV - DOAS and NDIR technologies, it determines the concentration of the measured gas by measuring the light intensity entering the sensor. The ultraviolet measurement part uses an imported xenon lamp light source and a high - resolution spectrometer. The software applies the UV - DOAS algorithm. Combined with a long - optical - path folded - back gas cell, it can accurately measure H2S and SO2 gases in KGD - SF - 501 gas without being interfered by background gases.
The product adopts a modular design for easy installation. It is equipped with a dew - point measurement unit that can provide real - time feedback on the trend of equipment signal changes. Operations such as calibration and standardization can be carried out through RS - 232/RS - 485 communication interfaces, which is convenient for customers to integrate and maintain.
Product Features
Technical Parameters
Parameter | Details |
Measured Components and Ranges | H2S: 100ppm; |
SO2: 100ppm; | |
CO: 1000ppm; | |
Dew - point Temperature: (-70 - 60) °C | |
Resolution | H2S/SO2: 0.1ppm; |
CO: 1ppm; | |
Dew - point Temperature: 0.1°C | |
Linear Error | ±1%F.S. |
Repeatability | ≤1% |
Preheating Time | 45min |
Zero - point Drift | ±3%F.S./7d |
Range - point Drift | ±3%F.S./7d |
Supply Voltage | 100 - 240VAC |
Power Consumption | 300W (Maximum Heating Power) / 100W (Steady - state Power) |
Ambient Temperature | (5 - 40) °C |
Relative Humidity | ≤95%RH |
Atmospheric Pressure | (70 - 106) KPa |
Communication Method | RS - 485/RS - 232, (4 - 20) mA |
![]() |
KGD SF 501 Online Monitoring System for Accurate Data Collection Images |